Compression Load Cell TC series
TC-PF2(T)☐☐N/kN-G
TEDS RoHSLoad cell for automotive pedal force measurement.
Made in Japan
- Features
- Thin, lightweight
Specifications
Model | Unit | Rated Capacity (R.C.) | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TC-PF2(T)☐☐N/kN-G | N | 5 | 10 | 20 | 50 | 100 | 200 | 500 | ||||||
kN | 1 | 2 | 3 | 5 | 10 | 20 | 40 | 50 | 100 | 200 | 500 | 1000 |
Model | TC-PF2(T)☐☐N/kN-G |
---|---|
Rated Capacity(R.C) | 500N, 1kN, 2kN |
Safe Overload Rating | 150%R.C. |
Rated Output (R.O.) | approx. 1mV/V(2000×10 6stain) |
Linearity | 0.3%R.0. (Target value) |
Hysteresis | 0.3%R.0. (Target value) |
Repeatability | 0.2%R.0. |
Zero Balance | ±10%R.O. |
Safe Excitation Voltage | AC. DC. 8V |
Input Terminal Resistance | 700Ω±5% |
Output Terminal Resistance | 700Ω±5% |
Insulation Resistance | 1000MΩ or more (DC50V) |
Compensated Temperature Range | 0℃ - 50℃(Withoug condensation) |
Permissible Temperature Range | -10℃ - +70℃(Without condensation) |
Temperature Effect on Zero Balance | ±0.5%R.O./10℃ |
Temperature Effect on Output | ±0.5%R.C./10℃ |
Cable | φ3mm 6-core robot cable 3m direct connection with NDI7P on the tip |
TEDS | Built-in NDIS7P Connector(PRC03-12A-10-7M) |
Environmental compliance | RoHS 10 |
*The specifications and appearance are subject to change without notice for improvement.
Outline Dimensions
Assembly drawing
Case
- Load cell for automotive pedal force measurement.
Use image
- By combining with Portable Digital Indicator TD-01 Portable, on-site verification can be done easily.