TEAC Load Cell site
Compression Load Cell TC series
Robot-cable

TC-AR(T)☐☐KN-G8

TEDS RoHS CE UKCA

Compact and lightweight makes it easy to install on existing equipment. In addition, since it is made of stainless steel (SUS630), it can be widely applied as a detector for devices

Made in Japan

Features
Compact, lightweight, corrosion-resistant, low-cost
TC-AR(T)☐☐KN-G8

Specifications

Model Unit Rated Capacity (R.C.)
TC-AR(T)☐☐KN-G8 N 0.5 1 1.5 2 3 5 10 20 50 100 200 500  
kN 1 2 3 5 10 20 30 50 100 200 300 500 1000
Rated Capacity (R.C.) Natural Frequency Weight (Approx.)
50kN 5.1tf 7.7kHz 1.8kg
100kN 10.2tf 11kHz 1.8kg
200kN 20.4tf 5.0kHz 3.1kg
Model TC-AR(T)☐☐KN-G8
Safe Overload Rating 150%R.C.
Rated Output (R.O.) 2mV/V ±1%
Linearity 0.1%R.O.
Hysteresis 0.15%R.O.
Repeatability 0.1%R.O.
Safe Excitation Voltage 15V
Input Terminal Resistance 425±50Ω
Output Terminal Resistance 350±5Ω
Insulation Resistance 1000MΩ or more (DC50V)
Compensated Temperature Range -10℃ - 70℃
Permissible Temperature Range -30℃ - 80℃
Temperature Effect on Zero Balance 0.1%R.O./10℃
Temperature Effect on Output 0.1%R.O./10℃
Cable φ8mm 6-core robot cable 5m direct connection with bare lead wires
Body material Stainless Steel
TEDS Built-in
Environmental compliance RoHS 10

Outline Dimensions

TC-AR(T)☐☐KN-G8 Outline Dimensions

Rated Capacity (R.C.) A B φC D φE φF G H R
20kN 2.04tf 25 22 60 15 12 42 4-M5
depth6
11 50
30kN 3.06tf 25 22 60 15 12 42 4-M5
depth6
11 50
50kN 5.1tf 40 35 100 30 24 80 4-M8
depth15
16 70
100kN 10.2tf 40 35 100 30 24 80 4-M8
depth15
16 70
200kN 20.4tf 45 40 120 30 33 90 4-M8
depth15
16 100