TEAC Load cell site
Compression Load Cell TC series
Robot-cable

TC-NSR(T)-G3

TEDS RoHS

It is a type that fixes with two tapped holes with a small, lightweight load cell.

Features
Small, Light weight, Screw mount
TC-NSR(T)-G3
Model Unit Rated.Capacity (R.C)
TC-NSR(T)-G3 N 0.5 1 1.5 2 3 5 10 20 50 100 200 500  
kN 1 2 3 5 10 20 30 50 100 200 300 500 1000
Rated.Capacity (R.C) Resonance Frequency Weight (Approx.)
1kN 102kgf 52.8kHz 16.3g
2kN 204kgf 55.5kHz 16.7g
Model TC-NSR(T)-G3
Safe Overload Rating 150%R.C.
Rated Output (R.O.) about 0.75mV/V
Non-linearity 1.0%R.O.
Hysteresis 1.0%R.O.
Repeatability 1.0%R.O.
Safe Excitation Voltage 7V
Input Terminal Resistance 350Ω±20Ω
Output Terminal Resistance 350Ω±20Ω
Insulation Resistance > 1000MΩ
Compensated Temperature Range TBA
Operating Temperature Range -20℃ - 70℃
Temperature Effect on Zero Balance 2%R.O./10℃
Temperature Effect on Output 1%R.C./10℃
Cable φ3, Shielded 6-Conductor wire, Robot-cable, 3m direct connection
Mounting 2-M2 tap on bottom
Material Stainless steel
TEDS Built-in
Environmental Regulations RoHS / REACH

TC-NSR(T)-G3 Outline Dimensions

Catalog PDF
Catalog (TEAC AMERICA) PDF
Catalog (TEAC EUROPE) PDF