TEAC Load Cell site
Low-profile Load Cell

Floor Scale

Robust, low-profile, high-stability, low-floor load cell floor scales

Features
  • Lineup : Thin type, standard type, simple waterproof type, ultra-compact type
  • Durable beam type load cell is used in the load detection section.
  • Stable operation even after long-term use
  • Material: Stainless steel
  • Environmental compliance: RoHS (10 substances)
Low-profile Load Cell Floor Scale
Ultra-compact type

TL-LF

Model Rated.Capacity (R.C) A B C E F H1 H2 Weight (Approx.) Linearity Safe Overload Rating Compensated Temperature Range
TL-LF 0.6, 1, 3kg 80 80 70 - - 33 31 0.4kg 0.03% 150% -10 - 40℃
Thin type

TL-PM

Model Rated.Capacity (R.C) A B C E F H1 H2 Weight (Approx.) Linearity Safe Overload Rating Compensated Temperature Range
TL-PM12 10, 20, 50kg 120 120 110 - - 19 17 0.7kg 0.25% 150% -10 - 50℃
TL-PM18 10, 20, 50kg 180 180 170 - - 19 16 1.4kg 0.25% 150% -10 - 50℃
TL-PM21 10, 20, 50kg 210 210 200 - - 19 16 1.7kg 0.25% 150% -10 - 50℃
Standard type

TL-PS

Model Rated.Capacity (R.C) A B C E F H1 H2 Weight (Approx.) Linearity Safe Overload Rating Compensated Temperature Range
TL-PS12 10, 20, 50kg 120 120 110 80 56 25 21 0.8kg 0.10% 150% -10 - 50℃
TL-PS18 10, 20, 50kg 180 180 170 120 150 25 21 2.0kg 0.10% 150% -10 - 50℃
TL-PS21 10, 20, 50, 100, 200kg 210 210 200 180 120 28 24 2.7kg 0.10% 150% -10 - 50℃
TL-PS25 10, 20, 50, 100, 200, 300, 400kg 250 250 240 180 220 28 24 3.8kg 0.10% 150% -10 - 50℃
TL-PS28 10, 20, 50, 100, 200, 300, 400kg 280 280 270 210 240 28 24 4.5kg 0.10% 150% -10 - 50℃
TL-PS33 20, 50, 100, 200, 300, 400kg 335 335 325 270 300 28 24 6.2kg 0.10% 150% -10 - 50℃
TL-PS42 50, 100, 200, 300, 400kg 420 420 410 350 380 32 27 11.1kg 0.10% 150% -10 - 50℃
TL-PS50 100, 200, 300, 400kg 500 500 490 340 440 33 28 16.8kg 0.10% 150% -10 - 50℃
TL-PS60 100, 200, 300, 400kg 600 600 490 340 440 33 27 18.2kg 0.10% 150% -10 - 50℃
Simple waterproof type (IP53 equivalent)

TL-PW

Model Rated.Capacity (R.C) A B C E F H1 H2 Weight (Approx.) Linearity Safe Overload Rating Compensated Temperature Range
TL-PW22 10, 20, 50, 100, 200kg 220 220 210 - - 30 24 3.4kg 0.10% 150% -10 - 50℃
TL-PW34 20, 50, 100, 200, 300, 400kg 345 345 335 - - 30 24 7.4kg 0.10% 150% -10 - 50℃
TL-PW43 50, 100, 200, 300, 400kg 430 430 420 - - 35 27 12.9kg 0.10% 150% -10 - 50℃
TL-PW53 100, 200, 300, 400kg 530 530 520 - - 35 30 21.9kg 0.10% 150% -10 - 50℃
TL-PW60 100, 200, 300, 400kg 600 600 590 - - 35 28 23.0kg 0.10% 150% -10 - 50℃
NOTE
  • Keep the installation surface of the platform level.
  • If the installation surface is tilted, it shows a different value from the actual load value.

Download

Instruction for use / English PDF