TEAC Load Cell site

Specifications

Bridge Voltage (BV) DC, 2.5/10V, ±10% (Current: 60mA max. Remote sensing available)
Signal input range ±3.2 mV/V
Equivalent input/TEDS Calibration range 0.3 mV/V to 3.2 mV/V
Calibration accuracy Within 0.1% FS (at 10V for BV and 0.5mV/V or more for sensor sensitivity)
Zero adjustment range ±2.0 mV/V
Accuracy Linearity Within 0.01% FS + and 1 digit (at an input of 1 mV/V or more)
Zero drift 0.5 μV/°C or less (RTI)
Gain drift Within ±0.005% FS/°C
A/D conversion rate 100 times/sec
Analog filter Selectable from 3, 10, 30, 100, 300 Hz (−12dB/oct)
Analog voltage output Voltage Approx. 2 V for 1 mV/V
Load register 2kΩ or more
TEDS function IEEE1451.4 Class 2 Mixed-mode interface
Note that the TEDS function cannot be used when remote sensing of excitation power supply is used.
Display Characters 14.6 mm high alphanumeric, shown by 7-segment green LED display
Range −19999 to 99999
Decimal point Position to be selectable
Refresh rate 4, 6, 10, 20 times/sec
Displayed items Calibration settings Zero CAL/Span CAL (TEDS CAL, Actual load CAL, Equiv. input CAL)
Function settings HI value, LO value, HH value, LL value, Comparison mode, Hysteresis, Near-zero, Digital filter, Analog filter, Motion detction, Zero tracking, Static strain, Digital zero, Zero offset, Hold mode, Key lock, Minimum scale, Refresh rate, Bridge voltage, B.C.D data refresh rate, RS232C, D/A converter
Hold functions Sample hold, Peak hold, Bottom hold, Peak-to-Peak hold, block-specified hold (Peak, Bottom, Peak-to-Peak)
External input / output signals Input Hold, Decision, Clear, Digital zero
Output 1a contact for each relay: HH, HI, OK, LO, LL, analog voltage
Power supply AC power rating: 100 to 240V ±10% 50 - 60Hz AC, 13W
Operating temperature range -10°C to 40°C
Storing temperature range −20°C to 60°C
Operating humidity range 85% RH or less (no condensation)
Standard Safety standard Installation class I, EN61010-1 Pollution degree 2 Overvoltage category II, CE marking
EMC VCCI(Class A), EN61326(Class A), EN61000-3-2, EN61000-3-3
External dimensions (W × H × D) Approx. 96 mm × 96 mm × 146 mm (protrusions not included)
Weight Approx. 950 g

Option-installed models
TD-260T AC(BCD)
TD-260T AC(232C)
TD-260T AC(D/A)

Outline Dimensions

Outline Dimensions

Accessories

Accesories for AC power model
  • Quick guide : 1
  • Flathead micro screwdriver : 1
  • Input/output connector plugs
    • B2L 3.50/18/180F SN BK BX or its equivalent : 1
    • BCZ 3.81/07/180F SN BK BX or its equivalent : 1