TEAC Load Cell site
Compression Load Cell TC series
Robot-cable

TC-LPR(T)☐☐N/KN-G6

TEDS RoHS CE UKCA

Load Button Removable thin load cell

Made in Japan

Features
It is thin and supports RoHS, and TEDS incorporation, a road button are removable
TC-LPR(T)☐☐N/KN-G6

Specifications

Model Unit Rated Capacity (R.C.)
TC-LPR(T)☐☐N/KN-G6 N 0.5 1 1.5 2 3 5 10 20 50 100 200 500  
kN 1 2 3 5 10 20 30 50 100 200 300 500 1000
Rated Capacity (R.C.) Natural Frequency Weight (Approx.)
500N 51.0kgf 2.5kHz 250g
1kN 102kgf 3.8kHz 250g
3kN 306kgf 7.3kHz 250g
5kN 510kgf Please contact us
10kN 1.02tf Please contact us
Model TC-LPR(T)☐☐N/KN-G6
Safe Overload Rating 120%R.C.(500N-3kN)
150%R.C.(5kN, 10kN)
Rated Output (R.O.) 1mV/V ±10%
Linearity 0.1%R.O.(500N-3kN)
0.3%R.O.(5kN, 10kN)
Hysteresis 0.1%R.O.(500N-3kN)
0.3%R.O.(5kN, 10kN)
Repeatability 0.05%R.O.
Safe Excitation Voltage 15V(500N-3kN)
12V(5kN, 10kN)
Input Terminal Resistance 382±10Ω
Output Terminal Resistance 350±3.5Ω
Insulation Resistance 1000MΩ or more (DC50V)
Compensated Temperature Range -10 - 70℃
Permissible Temperature Range -30 - 80℃
Temperature Effect on Zero Balance 0.1%R.O./10℃
Temperature Effect on Output 0.1%R.C./10℃
Cable φ6mm 6-core robot cable 5m direct connection with bare lead wires
Accessory Load button
TEDS Built-in
Environmental compliance RoHS 10

Outline Dimensions

TC-LPR(T)☐☐N/KN-G6 Outline Dimensions

Download

Catalogue / English PDF
Load cells & Indicators / English PDF
Instruction for use / English PDF